CMP472TS1
Milligard® PES 1.2/0.45 µm, Cartridge
pore size 1.2/0.45 μm, cartridge nominal length 20 in. (50 cm)
Synonym(s):
Milligard PES 20" 1.2/0.45 μm Cartridge
Select a Size
₹57,330.00
Select a Size
About This Item
₹57,330.00
Recommended Products
material
polyethersulfone membrane
polypropylene housing
polypropylene support
polypropylene vent cap
Quality Level
reg. compliance
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
sterility
non-sterile
Sterilization Compatibility
autoclavable compatible
steam-in-place compatible
product line
EMPROVE® Filter
Milligard®
feature
hydrophilic
manufacturer/tradename
Milligard®
parameter
1.38 bar max. differential pressure (20 psid) at 25 °C (Reverse)
5.52 bar max. differential pressure (80 psid) at 4-25 °C (Forward)
technique(s)
prefiltration: suitable
Related Categories
1 of 4
This Item | 56430AST | 56130AST | 56129AST |
---|---|---|---|
L × I.D. 1 cm × 2 mm | L × I.D. 1 cm × 4.6 mm | L × I.D. 1 cm × 4.6 mm | L × I.D. 1 cm × 2 mm |
particle size 5 μm | particle size 5 μm | particle size 5 μm | particle size 5 μm |
separation technique hydrophilic interaction (HILIC), normal phase | separation technique hydrophilic interaction (HILIC), normal phase | separation technique reversed phase | separation technique reversed phase |
matrix active group amino phase | matrix active group amino phase | matrix active group C18 (octadecyl) phase | matrix active group C18 (octadecyl) phase |
pore size 300 Å | pore size 300 Å | pore size 300 Å | pore size 300 Å |
matrix polymeric | matrix polymeric | matrix polymeric | matrix polymeric |
General description
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer wetting instructions of Filters with MILLIGARD® PES Membrane user guide
- Storage Statement: Please refer Filters with MILLIGARD® PES Membrane user guide
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Preparation Note
Autoclave wet 25x, 60 minute cycles at 128°C. In-line steam (wet): 10 forward cycles, 30 min.,
135 °C at ≤0.34 bar (5 psid) and 5 reverse cycles,
30 min., 135 °C at ≤0.07 bar (<1 psid)*.
*Devices were validated using steam at full differential pressure starting at 31 psid to a final differential pressure of 1 psid, resulting in a calculated average of 4 psid in forward and reverse directions.
Legal Information
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Customers Also Viewed
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service