1.00029
Acetonitrile
≥99.9% (GC), suitable for LC/MS, LiChrosolv®
동의어(들):
ACN, Cyanomethane, Ethyl nitrile, Methyl cyanide
About This Item
97 hPa ( 20 °C)
제품명
Acetonitrile, hypergrade for LC-MS LiChrosolv®
Agency
suitable for ASTM® 7968
suitable for ASTM® 7979
suitable for DIN 38407-42
suitable for EPA 1633
suitable for EPA 8327
suitable for GB 31604.35-2016
suitable for GB 5009.253-2016
suitable for ISO 21675 2019
Quality Level
규정 준수
suitable for FDA C-010.02
vapor density
1.41 (vs air)
vapor pressure
72.8 mmHg ( 20 °C)
97 hPa ( 20 °C)
제품 라인
LiChrosolv®
분석
≥99.9% (GC)
양식
liquid
autoignition temp.
524 °C
973 °F
expl. lim.
16 %
기술
HPLC: suitable
LC/MS: suitable
불순물
≤0.0001 meq/g Acidity
≤0.0002 meq/g Alkalinity
≤0.01% Water
≤10 ppb Al (Aluminium)
≤10 ppb Ca (Calcium)
≤10 ppb Fe (Iron)
≤10 ppb Mg (Magnesium)
≤5 ppb Any further metal (ICP-MS)
≤5 ppb K (Potassium)
≤50 ppb Na (Sodium)
증발 잔류물
≤1.0 mg/L
색상
APHA: ≤10
투과
191 nm, ≥25%
195 nm, ≥85%
200 nm, ≥96%
215 nm, ≥98%
230 nm, ≥99%
refractive index
n20/D 1.344 (lit.)
bp
81-82 °C (lit.)
SMILES string
CC#N
mp
−45 °C (lit.)
전이 온도
flash point 2 °C
density
0.786 g/mL at 25 °C (lit.)
응용 분야
PFAS testing
형식
neat
저장 온도
2-30°C
InChI
1S/C2H3N/c1-2-3/h1H3
InChI key
WEVYAHXRMPXWCK-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
애플리케이션
- Of the mobile phase in fast LC-MS quantification of illudane glycosides and analogs in bracken ferns.
- In the elution mixture to extract (fluoro)quinolone antibiotic compounds from the SDB-RPS extraction cartridge.
제조 메모
기타 정보
법적 정보
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2
Storage Class Code
3 - Flammable liquids
WGK
WGK 2
Flash Point (°F)
35.6 °F - closed cup
Flash Point (°C)
2.0 °C - closed cup
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
문서
HPTLC-MS was used to analyze stevioside and rebaudioside in artificial sweeteners, stevia plants, cola and isotonic drinks with a minimum of sample preparation.
HPTLC-MS was used to analyze stevioside and rebaudioside in artificial sweeteners, stevia plants, cola and isotonic drinks with a minimum of sample preparation.
Separation of null
Nonylphenols (NP) are ubiquitous substances that have been detected in highly diverse foodstuff. As breakdown products of nonylphenol ethoxylates, NP could end up in the aquatic environment. This article presents a rapid method for NP detection in surface water by planar solid phase extraction – planar yeast estrogen screen (pSPE-pYES).
프로토콜
Thin layer chromatography coupled with mass spectrometry does not require substantial sample preparation. Energy drinks can be applied without dilution directly onto the TLC plate.
Straightforward HPTLC-MS analysis of lactose in dairy products (milk or yoghurt) using only protein crash, centrifugation and dilution as sample preparation.
HPTLC–MS analysis of quinine in tonic water and caffeine in coffee and cola drinks. Tonic and cola drinks decarbonized through ultrasonication, and coffee extracted through PTFE filter.
BIOshell™ IgG 1000 Å C4 UHPLC Column for Improved Biomacromolecule Separations
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.