콘텐츠로 건너뛰기
Merck

GC Analysis of Trichloroanisole (TCA) and Precursors in Red Wine (Spiked) on SLB-5ms after SPME using 100 μm PDMS Fiber

GC Analysis of Trichloroanisole (TCA) and Precursors in Red Wine (Spiked) on SLB-5ms after SPME using 100 μm PDMS Fiber suitable for GC, application for SPME

Materials

SPME 파이버

제품 번호
설명
가격

SPME fiber assembly Polydimethylsiloxane (PDMS)

metal alloy fiber, df 100 μm(PDMS, needle size 23 ga, for use with autosampler

관련 제품

제품 번호
설명
가격

Inlet Liner, Direct (SPME) Type, Straight Design (unpacked)

pkg of 1 ea

부속물

제품 번호
설명
가격

Vials, screw top with phenolic open-top cap, pre-assembled

volume 4 mL, clear glass vial, O.D. × H 15 mm × 45 mm, tan PTFE/silicone septum

분석 컬럼

제품 번호
설명
가격

SLB®-5ms Capillary GC Column

L × I.D. 30 m × 0.25 mm, df 0.25 μm

표준 물질

제품 번호
설명
가격

2,4,6-Trichloroanisole

PESTANAL®, analytical standard

CONDITIONS

sample/matrix

1.5 mL red wine spiked with each analyte at 100 ng/L + 600 μL 5% potassium carbonate (K2CO3) + 240 mg sodium chloride (NaCl) + 60 μL acetic anhydride

SPME fiber

metal fiber coated with 100 μm PDMS (57928-U)

extraction

headspace, 50 °C for 30 min, with stirring

desorption process

250 °C for 3 min

column

SLB-5ms, 30 m x 0.25 mm I.D., 0.25 μm (28471-U)

oven

50 °C (1 min), 25 °C/min to 280 °C

detector

ECD, 290 °C

carrier gas

helium, 1.5 mL/min, constant

liner

0.75 mm I.D. SPME