A-005-M
Poly-ʟ-Lysine Hydrobromide
synthetic, liquid, 0.1 mg/mL, suitable for cell culture
Synonym(s):
Lysine
Select a Size
About This Item
Recommended Products
Product Name
Poly-L-Lysine Solution, 0.01%
biological source
synthetic
Quality Level
needle size
2.0 mm
sterility
sterile
form
liquid
mol wt
Mw 84000 Da
manufacturer/tradename
NovaSeptum®
concentration
0.01 % (w/v)
0.1 mg/mL
technique(s)
cell attachment: suitable
cell culture | mammalian: suitable
1 of 4
This Item | SAB4600054 | SAB4600093 | SAB4600113 |
---|---|---|---|
conjugate CF™ 594 conjugate | conjugate CF™ 488A conjugate | conjugate CF™ 594 conjugate | conjugate CF™ 594 conjugate |
Quality Level 100 | Quality Level 100 | Quality Level 100 | Quality Level 100 |
biological source rabbit | biological source rabbit | biological source chicken | biological source mouse |
antibody form affinity isolated antibody | antibody form affinity isolated antibody | antibody form affinity isolated antibody | antibody form purified immunoglobulin |
storage temp. −20°C | storage temp. −20°C | storage temp. −20°C | storage temp. −20°C |
form buffered aqueous solution | form buffered aqueous solution | form buffered aqueous solution | form buffered aqueous solution |
General description
The molecular weight of Poly-L-Lysine for cell culture can vary significantly, with lower molecular weight (30,000 Da) being less viscous and higher molecular weight (greater than 300,000 Da) having more binding sites per molecule. This product uses a Poly-L-Lysine of 84000 Da, yielding a solution viscosity for easy handling while providing sufficient binding sites for cell attachment.
Application
Biochem/physiol Actions
Quality
Preparation Note
1. Thaw Poly-L-Lysine solution at room temperature.
2. Dilute Poly-L-Lysine solution to the desired concentration in sterile water.
3. Fully coat the cell culture surface with diluted Poly-L-Lysine solution. Use 5 mL volume for 6-cm plates and 10 mL volume for 10-cm plates and T75 flasks.
4. Allow the cell culture vessel to sit at room temperature overnight.
5. Aspirate the Poly-L-Lysine solution the following day and rinse the vessel with sterile water followed by coating with desired ECM protein.
Legal Information
Storage Class Code
12 - Non Combustible Liquids
WGK
WGK 1
Flash Point(F)
Not applicable
Flash Point(C)
Not applicable
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Customers Also Viewed
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service