추천 제품
Quality Level
기술
titration: suitable
형광
λex 490 nm; λem 514 nm in 0.1 M Tris pH 8.0
적합성
suitable for fluorescence
SMILES string
Oc1ccc2c(Oc3cc(O)ccc3C24OC(=O)c5ccccc45)c1
InChI
1S/C20H12O5/c21-11-5-7-15-17(9-11)24-18-10-12(22)6-8-16(18)20(15)14-4-2-1-3-13(14)19(23)25-20/h1-10,21-22H
InChI key
GNBHRKFJIUUOQI-UHFFFAOYSA-N
유전자 정보
human ... PTPN1(5770), PTPRF(5792)
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Fluorescein dye is the most commonly used fluorescent probe. It is used to stain epithelial defects and analyse the integrity of corneal epithelium. Fluorescein is used in the diagnosis of corneal perforation. Oral or intravenous fluorescein is used in fluorescein angiography to detect diabetic retinopathy and choroidal neovascular membrane.
애플리케이션
Fluorescein has been used:
- in the permeability assay of Caco-2 cells
- to test its suitability to serve as lifetime fluorescence standards
- as a fluorophore for the fast recovery of fluorescence peaks and fluorophore concentration in the presence of hemoglobin
- as a fluorescent probe in oxygen radical absorbance capacity (ORAC) assay
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Eye Irrit. 2
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
Eyeshields, Gloves, type N95 (US)
이미 열람한 고객
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.