추천 제품
material
fused silica
파라미터
50-270 °C temperature (isothermal or programmed)
베타 값
313
df
0.20 μm
기술
gas chromatography (GC): suitable
길이 × I.D.
100 m × 0.25 mm
기질 활성군
Non-bonded; 1,5-Di(2,3-dimethylimidazolium)pentane bis(trifluoromethanesulfonyl)imide phase
응용 분야
agriculture
biofuels
chemicals and industrial polymers
clinical
environmental
food and beverages
petroleum
컬럼 유형
capillary extremely polar
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
Application: World′s first commercial column to rate over 100 on our GC column polarity scale. Selectivity most orthogonal to non-polar and intermediate polar phases, resulting in very unique elution patterns. Maximum temperature of 270 ºC is very impressive for such an extremely polar column. Great choice for separation of polarizable analytes (contain double and/or triple C-C bonds) from neutral analytes. Also a good GCxGC column choice. Launched in 2010.
USP Code: None
Phase:
USP Code: None
Phase:
- Non-bonded
- 1,5-Di(2,3-dimethylimidazolium)pentane bis(trifluoromethylsulfonyl)imide
- 50 °C to 270 °C (isothermal or programmed)
애플리케이션
Fast GC Analysis of Fatty Acid Methyl Esters Using a Highly Polar Ionic Liquid Column and its Application for the Determination of Trans Fatty Acid Contents in Edible Oils
This study presents a rapid method for analyzing trans fatty acid contents in edible oils using a fast gas chromatography (GC) technique combined with a highly polar ionic liquid column. The method significantly reduces analysis time to under 30 minutes, compared to over 90 minutes required by traditional methods from the American Oil Chemists’ Society (AOCS) and Japanese Oil Chemists’ Society (JOCS). The effectiveness of the fast GC method was confirmed through comparisons of trans fatty acid content in various oils, showing good agreement with results from the official methods. The study highlights the advantages of using m-TFPTAH for methyl esterification, which streamlines the process and enhances throughput.
Shinsuke Inagaki, Masahiko Numata (2015) https://doi.org/10.1007/s10337-014-2837-z
This study presents a rapid method for analyzing trans fatty acid contents in edible oils using a fast gas chromatography (GC) technique combined with a highly polar ionic liquid column. The method significantly reduces analysis time to under 30 minutes, compared to over 90 minutes required by traditional methods from the American Oil Chemists’ Society (AOCS) and Japanese Oil Chemists’ Society (JOCS). The effectiveness of the fast GC method was confirmed through comparisons of trans fatty acid content in various oils, showing good agreement with results from the official methods. The study highlights the advantages of using m-TFPTAH for methyl esterification, which streamlines the process and enhances throughput.
Shinsuke Inagaki, Masahiko Numata (2015) https://doi.org/10.1007/s10337-014-2837-z
- Analysis of Long-Chain Unsaturated Fatty Acids by Ionic Liquid Gas Chromatography: Utilizes the SLB®-IL111 capillary GC column for the precise and high-resolution analysis of fatty acids, highlighting its application in food chemistry to ensure quality and authenticity of agricultural products. (Weatherly et al., 2016).
- Characterisation of capillary ionic liquid columns for gas chromatography-mass spectrometry analysis of fatty acid methyl esters: Discusses the use of the SLB®-IL111 column in the detailed profiling of fatty acid methyl esters, demonstrating its efficiency in environmental and biochemical analysis, thereby underscoring its utility in complex sample analysis. (Zeng et al., 2013).
기타 정보
We offer a variety of chromatography accessories including analytical syringes
법적 정보
SLB is a registered trademark of Merck KGaA, Darmstadt, Germany
애플리케이션
제품 번호
설명
가격
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable