추천 제품
제품명
SUPELCOSIL™ LC-18-DB HPLC Column, 5 μm particle size, L × I.D. 25 cm × 4.6 mm
material
stainless steel column
Quality Level
Agency
suitable for USP L1
제품 라인
SUPELCOSIL™
특징
endcapped
제조업체/상표
SUPELCOSIL™
포장
1 ea of
라벨링 범위
11.0% Carbon loading
파라미터
0-70 °C temperature
400 bar pressure (5801 psi)
기술
HPLC: suitable
길이 × I.D.
25 cm × 4.6 mm
표면적
170 m2/g
표면 범위
surface coverage 3.1 μmol/m2
Matrix
silica gel, spherical particle platform
fully porous particle
기질 활성군
C18 (octadecyl) phase
입자 크기
5 μm
공극 크기
120 Å
작동 pH
2-7.5
응용 분야
food and beverages
호환성
for use with PTC-AA
분리 기술
reversed phase
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
SUPELCOSIL LC-DB phases are specially deactivated for basic compounds. These columns provide shorter retention, better peak shape, and higher efficiency for organic bases than can be obtained on other Type A silica reversed-phase columns.
애플리케이션
- OPTIMIZATION AND VALIDATION OF HPLC METHOD FOR TETRAMETHRIN DETERMINATION IN HUMAN SHAMPOO FORMULATION.: This study discusses the optimization and validation of a high-performance liquid chromatography (HPLC) method using SUPELCOSIL™ LC-18-DB HPLC Column for the analysis of tetramethrin in shampoo formulations (Zeric Stosic et al., 2016).
- Mass spectrometric characterization and HPLC determination of the main urinary metabolites of nimesulide in man.: Details a robust approach for identifying and quantifying nimesulide metabolites via HPLC, underscoring the column′s applicability in complex biological matrices (Carini et al., 1998).
법적 정보
SUPELCOSIL is a trademark of Sigma-Aldrich Co. LLC
가아드 카트리지
관련 제품
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
이미 열람한 고객
Xinghua Sun et al.
Anticancer research, 25(1A), 59-62 (2005-04-09)
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) method for the separation and quantification of L-methionine in plasma has been developed. After derivatization of plasma amino acids with o-phthalaldehyde (OPA), a 50 microl sample was loaded on a reversed-phase
M Carini et al.
Journal of pharmaceutical and biomedical analysis, 18(1-2), 201-211 (1998-12-24)
A study was undertaken for the characterization and quantitative determination of the main urinary metabolites of the non-steroidal anti-inflammatory drug (NSAID) nimesulide (4-nitro-2-phenoxy-methanesulfonanilide) in man following single oral administration (200 mg). Urines were collected from six healthy volunteers at 12
P A Hynning et al.
Clinical chemistry, 34(12), 2502-2503 (1988-12-01)
A high-performance liquid chromatographic (HPLC) method for determining verapamil and norverapamil in plasma is presented and compared with gas chromatography/mass spectrometry (GC-MS). The plasma samples were extracted at alkaline pH with hexane containing 2-butanol (20 mL/L) and then back-extracted into
D C Holland et al.
Journal of AOAC International, 78(4), 1067-1071 (1995-07-01)
A liquid chromatographic (LC) method is described for the simultaneous determination of the triazine herbicides, simazine (SIM), atrazine (ATZ), and propazine (PRO) in the 12.5-100 ppb range in catfish. The herbicides are extracted from catfish homogenates with ethyl acetate, followed
O Majid et al.
Therapeutic drug monitoring, 23(2), 163-168 (2001-04-11)
Recipients of organ transplants remain particularly dependent on prednisolone as part of their maintenance immunosuppression. Despite this, the pharmacokinetics of prednisolone have never been fully characterized in these patients, and consequently dosing remains empirical. Accurate monitoring of prednisolone, its primary
Chromatograms
application for SPE, application for HPLC자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..