UFC9030
Amicon® Ultra Centrifugal Filter, 30 kDa MWCO
sample volume 15 mL, regenerated cellulose membrane, MWCO 30 kDa
Synonim(y):
15 mL sample volume, 30 kDa MWCO, Centrifugal concentrator
About This Item
Materiały
polyethylene cap
polyethylene liner
polypropylene tube
regenerated cellulose membrane
regenerated cellulose support
styrene-butadiene housing
Poziom jakości
sterylność
non-sterile
linia produktu
Amicon®
producent / nazwa handlowa
Amicon® Ultra
sustainability
Greener Alternative Product
Parametry
15 mL sample volume
metody
protein extraction: suitable
protein purification: suitable
Długość
12.1 cm (4.807 in.)
Średnica
2.97 cm
powierzchnia filtracyjna
7.6 cm2
pojemność
15 mL
pojemność robocza
15 mL
wielkość porów
30 kDa MWCO
kategoria ekologicznej alternatywy
Warunki transportu
ambient
Opis ogólny
The vertical design and available membrane surface area provide fast sample processing, high sample recovery (typically greater than 90% of dilute starting solution), and the capability for 80-fold concentration. Solute polarization and subsequent fouling of the membrane are minimized by the vertical design, and a physical deadstop in the filter device prevents spinning to dryness and potential sample loss.
The concentrate is collected from the filter device sample reservoir using a pipetter, while the ultrafiltrate is collected in the provided centrifuge tube. The device can be spun in a swinging bucket or fixed angle rotor. With their vertical membrane design and deadstop, Amicon® Ultra 15 mL filters deliver the highest recovery with short spin times.
Zastosowanie
- Ultrafiltration with 30,000 Dalton molecular weight cutoff Ultracel® membrane.
- Concentration of biological samples containing antigens, antibodies, enzymes, nucleic acids, or microorganisms.
- Purification of macromolecular components found in tissue culture extracts or cell lysates and protein removal prior to HPLS.
- Concentration of dilute or pre-purified proteins from column eluents.
- Desalting, buffer exchange and protein dialysis.
Cechy i korzyści
- Ultracel® regenerated cellulose membrane with 30 kDa NMWCO delivers retentate recovery of greater than 90%.
- Vertical membrane reduces concentration polarization for ultra-fast spin times (as fast as 10–15 minutes).
- Heat-sealed membrane minimizes downstream extractables.
- 100% integrity tested for reliable performance.
- Convenient sample monitoring with translucent housing and volume gradations.
- Direct pipettor sample access eliminates processing step to recover concentrate.
- High concentration factors of 80–100X.
Postać fizyczna
Informacje prawne
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej