850168P

Avanti

XY-69

Avanti Research - A Croda Brand

동의어(들):

XY-69, TEA salt

로그인조직 및 계약 가격 보기


About This Item

실험식(Hill 표기법):
C91H143N8O27P3
Molecular Weight:
1874.07
UNSPSC 코드:
12352211
NACRES:
NA.25

분석

>99% (TLC)

양식

powder

포장

package of 1 × 50 μg (850168P-50UG)

제조업체/상표

Avanti Research - A Croda Brand

배송 상태

dry ice

저장 온도

−20°C (−15°C to −25°C)

SMILES string

CCN(CC)CC.CCN(CC)CC.CCN(CC)CC.O=C(C1=CC=C(/N=N/C2=CC=C(N(C)C)C=C2)C=C1)NCCOCCCCO[C@H]([C@H]([C@@H]3O)OP(O)(O)=O)[C@H](OP(OC[C@H](OC(CCCCCCCCCCCCCCC)=O)COC(CCCCCNC(C4=CC(C5=C6C=CC(C=C6OC7=C5C=CC(O)=C7)=O)=C(C(O)=O)C=C4)=O)=O)(O)=O)[C@H](O)[C@@H]3O.O=P(O)=O

InChI

1S/C73H97N5O24P2.3C6H15N.HO3P/c1-4-5-6-7-8-9-10-11-12-13-14-15-17-23-63(82)99-55(46-97-62(81)22-18-16-19-38-74-72(87)49-26-35-56(73(88)89)59(43-49)64-57-36-33-53(79)44-60(57)100-61-45-54(80)34-37-58(61)64)47-98-104(93,94)102-69-67(85)65(83)66(84)68(101-10

InChI key

IVJBYULSDJJAMV-HWQKZJNZSA-N

애플리케이션


  • Fluorogenic XY-69 in Lipid Vesicles for Measuring Activity of Phospholipase C Isozymes.: This study describes the use of fluorogenic XY-69 encapsulated within lipid vesicles to measure the enzymatic activity of Phospholipase C isozymes, offering a novel tool for biochemical assays in membrane mimetic environments (Carr et al., 2021).

  • A High-Throughput Assay to Identify Allosteric Inhibitors of the PLC-γ Isozymes Operating at Membranes.: This research presents a high-throughput screening method utilizing XY-69 to identify allosteric inhibitors of PLC-γ isozymes, demonstrating significant implications for therapeutic development (Huang et al., 2020).

  • A membrane-associated, fluorogenic reporter for mammalian phospholipase C isozymes.: This article introduces a membrane-associated, fluorogenic reporter system using XY-69 to study mammalian phospholipase C isozymes, enhancing the understanding of enzyme regulation and interaction with lipid membranes (Huang et al., 2018).

포장

2 mL Amber Serum Vial with Stopper and Crimp Cap (850168P-50UG)

법적 정보

Avanti Research is a trademark of Avanti Polar Lipids, LLC

Storage Class Code

13 - Non Combustible Solids

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 문서 section.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.